Description
Control System KNX WS1000 Color
• Status: 18.04.2016 • Errors excepted. Subject to technical changes.
Automatic functions for coolings and air-conditioning units:
•
Switch on daily above a selectable indoor temperature
•
Night mode (with adjustment of time and temperature until cooling takes
place)
•
Cancel ventilation when cooling/air-conditioning unit is active
Automatic ventilation functions:
•
Ventilation above a selectable indoor temperature (can be switched off)
•
Ventilation above a selectable air humidity level in the room
(can be switched off)
•
Winter operation: supply air will be closed below a selectable outdoor
temperature (can be switched off)
•
Summer operation: supply air will be shut off if outdoor temperature is higher
than room temperature
•
Adjustable minimum and maximum speeds for motorised fans
•
Night-time re-cooling (settable running times)
•
Daily forced ventilation (settable running times)
•
Additionally with roof ventilators WL610 and WL305: recirculating air for heat
recovery; recirculating air to avoid condensation
•
Cancel ventilation when cooling/air-conditioning unit is active
Automatic functions for light:
•
Switch on daily (settable running times, with and without twilight recognition)
•
Switch on at twilight
Automatic functions for roof gutter heatings:
•
Switch on within an adjustable temperature range