Automatic settings
Control System KNX WS1000 Color
• Status: 18.04.2016 • Errors excepted. Subject to technical changes.
Confirm your setting by pressing
OK
.
Press the button to set the ventilation running time. However the window will only
open if the specified outdoor temperature is reached. At the end of a ventilation period,
the normal automatic ventilation according to temperature and air humidity will be ex-
ecuted.
Press
Select
to select the time periods. Activate one or more periods on the list. The
periods can be individually customised (see below).
Confirm your setting by pressing
OK.
To change any of the time periods, press Timer.
3.3. Set timer
Press the button to activate or deactivate the movement range limitation for this win-
dow at low outdoor temperatures.
The conditions for the triggering of the movement limitation (outdoor temperature, pe-
riod) are defined in the "General Settings" menu.
System > Automatic Setttings > General Settings > Movement Limitation
3.3. Set movement limitations (windows)
Confirm your setting by pressing
OK.
Press the button to set the movement position when movement limitation is active.
The button will only be activated once the movement limitation has been activated.
Input the maximum movement position in % using the arrow buttons (0% = closed,
100% = fully open). Default: 50%.
The window can be reopened fully by hand.
Confirm your setting using the OK button.
Confirm your setting by pressing
OK.
Press the button to set the outdoor temperature block. The effect of the block is that the
window remains in the current position. The outdoor temperature block can, for exam-
ple, be used if the window should not be used for ventilation in winter (cold protection
for plants).
Timed Ventilation
Movement Limitation
to Position
Outdoor Temp.