29
Automatic settings
Control System KNX WS1000 Color
• Status: 18.04.2016 • Errors excepted. Subject to technical changes.
Press the button to select the indoor sensor the control system will use for this awning
(Pre-setting: first sensor in the list). As long as “
No Sensor
” is selected, the indoor
temperature will not be taken into account by the control system for this shade.
Confirm your setting with the
OK
button.
Press the button to set the indoor temperature block. Until an indoor sensor is selected,
the indoor temperature block will not be active.
The interior blocking temperature enables the use of solar energy to warm the room.
When the indoor temperature is below the set value, e.g. in the morning, the shading
will remain retracted despite the sunshine.
As soon as the set indoor temperature is exceeded, the block is released and the shade
is activated.
When the indoor temperature drops once again, the block is reactivated when the tem-
perature drops below the pre-set value by more than 3.0°C (hysteresis). Note that the
shade only retracts once the retraction delay time has elapsed.
System > Automatic Settings > General Settings > Movement Delays
3.3. Adjust movement delays (shading)
Set temperature: With the arrow keys, adjust the value for the desired room tempera-
ture. Default setting: 25.0 °C.
Disable block: If the awning should be deployed to offer shade regardless of the indoor
temperature, press the
Off
button.
Confirm your setting with the
OK
button.
Press the button to set the outdoor temperature block. The block only applies to auto-
matic operation; no shading occurs based on light intensity or the position of the sun.
Even when an outdoor blocking temperature is active, the drive will respond to wind
and rain alarms, as well as manual movement commands.
Please note that the shade rails or other mechanical components can remain iced even
when the outdoor temperature has already risen to a relatively high value.
The drive and hangings may be damaged if a firmly frozen
outdoor shading is moved!
Set temperature: If the awning should be blocked when the outdoor temperature is
low, set the value recommended by the manufacturer using the arrow keys. Default
Sensor Selection
Indoor Temp.
Outdoor Temp.