Automatic settings
Control System KNX WS1000 Color
• Status: 18.04.2016 • Errors excepted. Subject to technical changes.
Deactivate: If ventilation is to take place via the window regardless of the frost risk, se-
lect
No
(default setting).
Confirm your setting with the
OK
button.
Press the button to set the wind alarm. The wind alarm protects the unit and equipment
from damage by closing the window. The wind alarm will also close manually opened
windows.
Adjust values: Use the arrow keys to adjust the value for wind speed and the length of
time by which it must have been exceeded.
Disable: If the window should not react to the wind, select
Never close
(default set-
ting).
Confirm your setting with the
OK
button.
A wind alarm triggered for the drive will be maintained for 5 minutes. If during these 5
minutes the saved value is exceeded again, the holding time begins again.
Press the button to enable or disable the rain alarm. The rain alarm protects against
moisture damage by closing the window. The rain alarm will also close manually
opened windows.
Enable: If the window should be closed when there is rain, select
Yes.
Disable: If the window should remain open when there is rain, select
No
(default set-
ting).
Confirm your setting with the
OK
button.
When precipitation begins, depending on the amount of rain and
the temperature, some time may pass before the precipitation is
recognised by the weather station. The operating time taken to
close the window must also be included in this calculation.
Moisture-sensitive objects should therefore not be placed within the
area of the automatic window.
Press the button to enable or disable gap opening when a rain alarm triggers. The func-
tion is only active if the rain alarm is switched on. With gap opening, the window can
be opened a little despite a rain alarm.
Enable: If gap opening should be active when it rains, select
Yes
.
Wind Alarm
Rain Alarm
Gap Ventilation