Electrical Operation and Maintenance Manual for Control Cabinet of EC2-S Industrial Robot
105
5. Replace the encoder;
6. Replace the drive;
7. Restart the electric cabinet.
1.3.1.30 Alarm 747
Fault Description: An error occurred in the cabinet temperature. And the temperature of the control
board is higher than the selected threshold.
Fault Reasons: An error occurred in the cabinet temperature. And the temperature of the control board
is higher than the selected threshold.
Solutions:
1. Check whether the drive parameters regarding the temperature setting of the control board are
reasonable;
2. Check whether the heat dissipation and ventilation environment of the cabinet are good;
3. Restart the electric cabinet.
1.3.1.31 Alarm 748
Fault Description: An error occurred in the cabinet temperature. And the temperature of its base plate
is higher than the selected threshold.
Fault Reasons: An error occurred in the cabinet temperature. And the temperature of its base plate is
higher than the selected threshold.
Solutions:
1. Check whether the drive parameters regarding the temperature setting of the base plate are
reasonable;
2. Check whether the heat dissipation and ventilation environment of the cabinet are good;
3. Restart the electric cabinet.
1.3.1.32 Alarm 750
Fault Description: An error occurred in motor temperature. And the temperature of the position sensor
is higher than the selected threshold.
Fault Reasons: An error occurred in motor temperature. And the temperature of the position sensor is
higher than the selected threshold.
Solutions:
1. Check the temperature of the motor;
2. Check whether the heat dissipation and ventilation environment of the cabinet are good;
3. Restart the electric cabinet.
1.3.1.33 Alarm 752
Fault Description: This is a power supply error. And the value of the DC bus bar is lower than the
selected threshold.
Fault Reasons: This is a power supply error. And the value of the DC bus bar is lower than the selected
threshold.
Solutions:
Summary of Contents for EC2-S
Page 2: ......
Page 4: ......
Page 10: ......
Page 34: ...EFORT INTELLIGENT EQUIPMENT CO LTD 24 15 19 21 front left side panel bottom plate 16 17 20 18...
Page 84: ...EFORT INTELLIGENT EQUIPMENT CO LTD 74...
Page 85: ...Electrical Operation and Maintenance Manual for Control Cabinet of EC2 S Industrial Robot 75...
Page 86: ...EFORT INTELLIGENT EQUIPMENT CO LTD 76...
Page 87: ...Electrical Operation and Maintenance Manual for Control Cabinet of EC2 S Industrial Robot 77...
Page 88: ...EFORT INTELLIGENT EQUIPMENT CO LTD 78...
Page 89: ...Electrical Operation and Maintenance Manual for Control Cabinet of EC2 S Industrial Robot 79...
Page 90: ...EFORT INTELLIGENT EQUIPMENT CO LTD 80...
Page 91: ...Electrical Operation and Maintenance Manual for Control Cabinet of EC2 S Industrial Robot 81...
Page 92: ...EFORT INTELLIGENT EQUIPMENT CO LTD 82...
Page 120: ......