Input/output addresses
35
02/09 AWB2723-1612en
Outputs
:
Byte 0:
If the evaluation of the diagnostic bit shows that there is
extended diagnostic information, details on this can be
determined by evaluation of the acyclic diagnostics of the
PROFIBUS-DP.
Bit
Designation
Meaning
0
NC1 = Normally Close
0: contact actuated
1: contact not actuated
1
NO = Normally Open
0: contact not actuated
1: contact actuated
2
not used
-
3
not used
-
4
F = Failure
0: No diagnostic alarm
1: Diagnostics available
5
not used
-
6
P = modules present
0: Modules not available
1: Modules available
7
not used
-
7
6
5
4
3
2
1
0
-
-
-
-
-
-
-