Dynamic Flow Computers
SFC332L Manual
Modbus Data
– 4-22
Modbus Address Table
– 32 Bits
ADDRESS DESCRIPTION
DECIMAL READ/WRITE
Date: 8/1/2019
The following registers (4465-4559) are only good for version sfc1.38 and higher)
4465
Meter #1 BTU Override
3 Inferred
Read/Write
4467
Meter #2 BTU Override
3 Inferred
Read/Write
4469
Meter #1 Base Density Override
6 Inferred
Read/Write
4471
Meter #2 Base Density Override
6 Inferred
Read/Write
4473
AGA8
– Mol % of Methane
4 Inferred
Read/Write
4475
AGA8
– Mol % of Nitrogen
4 Inferred
Read/Write
4477
AGA8
– Mol % of Carbon Dioxide
4 Inferred
Read/Write
4479
AGA8
– Mol % of Ethane
4 Inferred
Read/Write
4481
AGA8
– Mol % of Propane
4 Inferred
Read/Write
4483
AGA8
– Mol % of Water
4 Inferred
Read/Write
4485
AGA8
– Mol % of Hydrogen Sulfide
4 Inferred
Read/Write
4487
AGA8
– Mol % of Hydrogen
4 Inferred
Read/Write
4489
AGA8
– Mol % of Carbon Monoxide
4 Inferred
Read/Write
4491
AGA8
– Mol % of Oxygen
4 Inferred
Read/Write
4493
AGA8
– Mol % of i-Butane
4 Inferred
Read/Write
4495
AGA8
– Mol % of n-Butane
4 Inferred
Read/Write
4497
AGA8
– Mol % of i-Pentane
4 Inferred
Read/Write
4499
AGA8
– Mol % of n-Pentane
4 Inferred
Read/Write
4501
AGA8
– Mol % of n-Hexane
4 Inferred
Read/Write
4503
AGA8
– Mol % of i-Hexane
4 Inferred
Read/Write
4505
AGA8
– Mol % of n-Heptane
4 Inferred
Read/Write
4507
AGA8
– Mol % of n-Octane
4 Inferred
Read/Write
4509
AGA8
– Mol % of n-Nonane
4 Inferred
Read/Write
4511
AGA8
– Mol % of n-Decane
4 Inferred
Read/Write
4513
AGA8
– Mol % of Helime
4 Inferred
Read/Write
4515
AGA8
– Mol % of Argon
4 Inferred
Read/Write
4517
Meter#1 PID Output %
2 Inferred
Read/Write
4519
Meter#1 PID Flow
2 Inferred
Read/Write
4521
Meter#1 PID Flow Set Point
2 Inferred
Read/Write
4523
Meter#1 PID Flow Controller Gain
2 Inferred
Read/Write
4525
Meter#1 PID Flow Controller Reset(M
2 Inferred
Read/Write
4527
Meter#1 PID Pressure Maximum
2 Inferred
Read/Write
4529
Meter#1 PID Pres.Set Point
2 Inferred
Read/Write
4531
Meter#1 PID Pres.Controller Gain
2 Inferred
Read/Write
4533
Meter#1 PID Pres.Controller Reset(M.)
2 Inferred
Read/Write
4535
Meter#1 PID Minimum Output %
2 Inferred
Read/Write
4537
Meter#1 PID Maximum Output %
2 Inferred
Read/Write
4539
Meter#2 PID Output %
2 Inferred
Read/Write
4541
Meter#2 PID Flow Maximum
2 Inferred
Read/Write
4543
Meter#2 PID Flow Set Point
2 Inferred
Read/Write
4545
Meter#2 PID Flow Controller Gain
2 Inferred
Read/Write
4547
Meter#2 PID Flow Controller Reset(M.)
2 Inferred
Read/Write
4549
Meter#2 PID Pressure Maximum
2 Inferred
Read/Write
4551
Meter#2 PID Pres.Set Point
2 Inferred
Read/Write
4553
Meter#2 PID Pres.Controller Gain
2 Inferred
Read/Write
4555
Meter#2 PID Pres.Controller Reset(M.)
2 Inferred
Read/Write
4557
Meter#2 PID Minimum Output %
2 Inferred
Read/Write
4559
Meter#2 PID Maximum Output %
2 Inferred
Read/Write
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...