Dynamic Flow Computers
SFC332L Manual
Data Entry
— 2-29
Date: 8/1/2019
Boolean Points
0100 through 0199
Meter #1 Boolean Points
0200 through 0299
Meter #2 Boolean Points
1
st
digit
– always 0, 2
nd
digit
– meter number.
0n01
Gross Flow Pulses
0n02
Net Flow Pulses
0n03
Mass Flow Pulses
0n04
N/A
0n05
Meter Active
0n06
Spare
0n07
Any Alarms
0n08-0n10
Spare
0n11
DP Override in use
0n12
Temperature Override in use
0n13
Pressure Override in use
0n14
Density Override in use
0n15
Densitometer Temperature Override in use
0n16-0n19
Spare
0n20
Flow Rate High Alarm
0n21
Flow Rate Low Alarm
0n22
Temperature High Alarm
0n23
Temperature Low Alarm
0n24
Pressure High Alarm
0n25
Pressure Low Alarm
0n26
Density High Alarm
0n27
Density Low Alarm
301
through
0699
Spare
0701
through
0799
Station Boolean Points
0701
Station Gross Flow Pulses
0702
Station Net Flow Pulses
0703
Station Mass Flow Pulses
0704-0710 Spare
0711
Run Switch
0801 through 0899 Command Boolean Points
0801
Request Snapshot Report
0802
Alarm Acknowledge
0803
End Meter #1 Batch
0804
End Meter #2 Batch
0805
End Meter#1 and Meter#2 Batch
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...