Dynamic Flow Computers
SFC332L Manual
Modbus Data
– 4-24
Modbus Address Table
– 32 Bits
ADDRESS DESCRIPTION
DECIMAL READ/WRITE
Date: 8/1/2019
*Note
: no of decimal position is contengined on the resolution setting.
Temperature Resolution (2794)
Pressure Reslution (2795)
4687
Meter #1 Density/Gravity @4mA
4 or 1 Inferred
Read/Write
4689
Meter #1 Density/Gravity @20mA
4 or 1 Inferred
Read/Write
4691
Meter #1 Density/Gravity Lo-Limit
4 or 1 Inferred
Read/Write
4693
Meter #1 Density/Gravity Hi-Limit
4 or 1 Inferred
Read/Write
4695
Meter #1 Density/Gravity Maintenance
4 or 1 Inferred
Read/Write
4697
Meter #1 Density Temp. @4mA
0,1,2 Inferred*
Read/Write
4699
Meter #1 Density Temp. @20mA
0,1,2 Inferred*
Read/Write
4701
Meter #1 Density Temp. Lo-Limit
0,1,2 Inferred*
Read/Write
4703
Meter #1 Density Temp. Hi-Limit
0,1,2 Inferred*
Read/Write
4705
Meter #1 Density Temp. Maintenance
0,1,2 Inferred*
Read/Write
4707
Meter #1 DP High @4mA
4 Inferred
Read/Write
4709
Meter #1 DP High. @20mA
4 Inferred.
Read/Write
4711-4715
Spare
4717
Meter #1 Dens.Correction Factor
5 Inferred
Read/Write
4719
Meter #1 Dens.Period Low Limit
3 Inferred
Read/Write
4721
Meter #1 Dens.Period High Limit
3 Inferred
Read/Write
4723-4725
Spare
4727
Meter #2 DP Low @4mA
4 Inferred
Read/Write
4729
Meter #2 DP Low @20mA
4 Inferred
Read/Write
4731
Meter #2 DP Low Lo-Limit
4 Inferred
Read/Write
4733
Meter #2 DP Low Hi-Limit
4 Inferred
Read/Write
4735
Meter #2 DP Low Maintenance
4 Inferred
Read/Write
4737
Meter #2 Temperature @4mA
0,1,2 Inferred*
Read/Write
4739
Meter #2 Temperature @20mA
0,1,2 Inferred*
Read/Write
4741
Meter #2 Temperature Lo-Limit
0,1,2 Inferred*
Read/Write
4743
Meter #2 Temperature Hi-Limit
0,1,2 Inferred*
Read/Write
4745
Meter #2 Temperature Maintenance
0,1,2 Inferred*
Read/Write
4747
Meter #2 Pressure @4mA
0,1 Inferred*
Read/Write
4749
Meter #2 Pressure @20mA
0,1 Inferred*
Read/Write
4751
Meter #2 Pressure Lo-Limit
0,1 Inferred*
Read/Write
4753
Meter #2 Pressure Hi-Limit
0,1 Inferred*
Read/Write
4755
Meter #2 Pressure Maintenance
0,1 Inferred*
Read/Write
4757
Meter #2 Density/Gravity @4mA
4 or 1 Inferred
Read/Write
4759
Meter #2 Density/Gravity @20mA
4 or 1 Inferred
Read/Write
4761
Meter #2 Density/Gravity Lo-Limit
4 or 1 Inferred
Read/Write
4763
Meter #2 Density/Gravity Hi-Limit
4 or 1 Inferred
Read/Write
4765
Meter #2 Density/Gravity Maintenance
4 or 1 Inferred
Read/Write
4767
Meter #2 Density Temp. @4mA
0,1,2 Inferred*
Read/Write
4769
Meter #2 Density Temp. @20mA
0,1,2 Inferred*
Read/Write
4771
Meter #2 Density Temp. Lo-Limit
0,1,2 Inferred*
Read/Write
4773
Meter #2 Density Temp. Hi-Limit
0,1,2 Inferred*
Read/Write
4775
Meter #2 Density Temp. Maintenance
0,1,2 Inferred*
Read/Write
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...