Modbus Data 4-43
Date: 8/1/2019
Example:
M2 Density Correction Factor is changed from 1.00000 to 1.10000
8501
Last Audit Date mmddyy
00 00 C8 C8 (Hex), 051400 (Digit)
– May 14, 2000
8503
Last Audit Time hhmmss
00 03 0d 40 (Hex), 200000(Digit)
– 8 PM
8505
Old Value (Decimal Inferred in the 4
th
byte of 8513)
00 01 86 a0 (Hex) 100000 (Digit)
4
th
byte of 8513 = 5 (Decimal Places)
result = 1.00000
8507
New Vaule(Decimal Inferred in the 4
th
byte of 8513)
00 01 ad b0 (Hex) 110000 (Digit)
4
th
byte of 8513 = 5 (Decimal Places)
Rsult = 1.10000
8509
Meter #1 Batch Total (Meter #1 Flow Resolution Inferred)
00 00 01 F4 (Hex), 500 (Digit)
Assume Meter#1 Flow Resolution is 1
Result = 50.0
8511
Meter #1 Batch Total (Meter #2 Flow Resolution Inferred)
00 00 01 F4 (Hex), 500 (Digit)
Assume Meter#2 Flow Resolution is 1
Result = 50.0
8513 Code Flag
40 26 3a 05 in Hex
1st Byte
– Config Code
in Binary 01000000
– bit 6 is on (2 Meters
Configuration)
2
nd
Byte
– NO
26 (Hex) 38 (Digit) Meter#2 Density,
3
rd
Byte
– Audit Code –
3A(Hex) 58 (Digit)
– Density Correction Factor
4
th
Byte
–
Decimal Places
– 05(Hex) – 5 Decimal Places
NOTE:
When Audit Code = 180, then the following Modbus Addresses store the
parameters indicated.
8501
System Start Date
8503
System Start Time
8505
System Failed Date
8507
System Failed Time
8509
Not Used
8511
Not Used
P
R E V I O U S
A
U D I T
D
A T A
A
R E A
E
N D S
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...