Dynamic Flow Computers
SFC332L Manual
Modbus Data
– 4-25
Modbus Address Table
– 32 Bits
ADDRESS DESCRIPTION
DECIMAL READ/WRITE
Date: 8/1/2019
4777
Meter #2 DP High @4mA
4 Inferred
Read/Write
4779
Meter #2 DP High @20mA
4 Inferred
Read/Write
4781-4785
Spare
4787
Meter #2 Dens.Correction Factor
5 Inferred
Read/Write
4789
Meter #2 Dens.Period Low Limit
3 Inferred
Read/Write
4791
Meter #2 Dens.Period High Limit
3 Inferred
Read/Write
4793-4795
Spare
4797
Spare#1 @4mA
0,1,2,3,4 Inferred* Read/Write
4799
Spare#1 @20mA
0,1,2,3,4 Inferred* Read/Write
4801
Spare#1 Lo-Limit
0,1,2,3,4 Inferred* Read/Write
4803
Spare#1 Hi-Limit
0,1,2,3,4 Inferred* Read/Write
4805
Spare#1 Maintenance
0,1,2,3,4 Inferred* Read/Write
4807
Spare#2 @4mA
0,1,2,3,4 Inferred* Read/Write
4809
Spare#2 @20mA
0,1,2,3,4 Inferred* Read/Write
4811
Spare#2 Lo-Limit
0,1,2,3,4 Inferred* Read/Write
4813
Spare#2 Hi-Limit
0,1,2,3,4 Inferred* Read/Write
4815
Spare#2 Maintenance
0,1,2,3,4 Inferred* Read/Write
4817
GM/CC Conversion Factor
6 Inferred
Read/Write
4819
Weight of H2O
4 Inferred
Read/Write
4821
Reference Density
4 Inferred
Read/Write
4823
Run Switch Low Set Point
2 Inferred
Read/Write
4825
Run Switch High Set Point
2 Inferred
Read/Write
4827
Atmospheric Pressure PSIA
3 Inferred
Read/Write
4829
Pulse Output Volume #1 Pulses/Unit
3 Inferred
Read/Write
4831
Pulse Output Volume #2 Pulses/Unit
3 Inferred
Read/Write
4833
Analog Output #1 at 4 mA
4835
Analog Output #1 at 20 mA
4837
Analog Output #2 at 4 mA
4839
Analog Output #2 at 20 Ma
4841
Calibration
– Meter #1 Mass Flowrate Override
3 Inferred
Read/Write
4843
Calibration
– Meter #2 Mass Flowrate Override
3 Inferred
Read/Write
4845-4849
Spare
The following registers (4851-4869) are only good for version sfc.1.36 and higher
4851
Meter #1 Density Press. @4mA
0,1 Inferred*
Read/Write
4853
Meter #1 Density Press. @20mA
0,1 Inferred*
Read/Write
4855
Meter #1 Density Press. Lo-Limit
0,1 Inferred*
Read/Write
4857
Meter #1 Density Press. Hi-Limit
0,1 Inferred*
Read/Write
4859
Meter #1 Density Press. Maintenance
0,1 Inferred*
Read/Write
4861
Meter #2 Density Press. @4mA
0,1 Inferred*
Read/Write
4863
Meter #2 Density Press. @20mA
0,1 Inferred*
Read/Write
4865
Meter #2 Density Press. Lo-Limit
0,1 Inferred*
Read/Write
4867
Meter #2 Density Press. Hi-Limit
0,1 Inferred*
Read/Write
4869
Meter #2 Density Press. Maintenance
0,1 Inferred*
Read/Write
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...