Dynamic Flow Computers
SFC332L Manual
Data Entry
— 2-25
Date: 8/1/2019
F
L O W
C
O M P U T E R
D
I S P L A Y
A
S S I G N M E N T
Up to 16 assignments can be displayed. The Flow Computer will scroll through them at the assigned delay
time. Active alarm will automatically prompt on the screen if alarm conditions exist. To read active alarms,
use the diagnostic screen.
Assignment
4 Digit Selection
, where
1
st
Digit:
0: Forward
1: Reverse
2
nd
Digit:
1: Meter#1
2: Meter#2
3: Station
3
rd
and 4
th
Digit:
Selection
(see table below)
Flow Rate
Batch Total
Daily Total
Cumulative
Total
Previous
Daily
Previous Batch
Gross
01
04
07
10
13
16
Net
02
05
08
11
14
17
Mass
03
06
09
12
15
18
Other Assignments
DP
37
Time/Date
50
DP L/H
42
Alarms
51
Temperature
38
Calibrated Mass Flow Rate
52
Pressure
39
*Prog.Var#7791
53
Density
40
*Prog.Var#7792
54
Density Temperature
41
*Prog.Var#7793
55
Specific Gravity
43
*Prog.Var#7794
56
Density@60
44
*Prog.Var#7795
57
Density Period
45
*Prog.Var#7796
58
Uncorrected Density
46
*Prog.Var#7797
59
Product
47
*Prog.Var#7798
60
Density Frequency
48
Densitometer Pressure
61
Spare #1/#2
49
Examples:
0113
Display Meter #1 Forward Previous Daily Gross Total
0104
Display Meter #1 Forward Batch Gross Total
1104
Display Meter #1 Reverse Batch Gross Total
1206
Display Meter #2 Reverse Batch Mass Total
138
Display Meter #1 Temperature
*Note:
only for version flow computer.1.36 and higher
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...