Dynamic Flow Computers
SFC332L Manual
Data Entry
— 2-7
Date: 8/1/2019
M
E T E R
D
A T A
Meter ID
Up to 8 characters. This function will serve as meter tag.
Flow Equation Type (1-4)
0 = AGA3 (OLD)
1 = API 14.3 (NEW AGA3)
2 = Wedge
3 = Venturi
4 = AGA7 (TURBINE or Frequency Type Input)
Select the desired calculation mode. API 14.3 is the latest orifice calculations introduced in 1994 All new
installations are recommended to use API 14.3 for orifice calculations.
Flow Rate Low/High Limit
The high/low flow rate alarm is activated, when net flow rate exceeds or is below the set limit. The alarm
will be documented with time, date, and totalizer.
Flow Rate Resolution
Flow rate indication will carry the programmed decimal positions.
Volume Units
Select desired units 0=BBL, 1=GAL, 2=CF, or 3=MCF. The SFC332L Flow Computer will perform the
proper conversion routine from barrels to gallons to cubic feet.