Dynamic Flow Computers
SFC332L Manual
Modbus Data 4-45
Date: 8/1/2019
INPUT ASSIGNMENTS
1
– Analog Input #1
2
– Analog Input #2
3
– Analog Input #3
4
– Analog Input #4
5
– RTD#1
6.- RTD#2
10
– Multi.Variable
ADDRESS
DESCRIPTION
2798
Meter #1 BS&W Assignment
2799
Meter #1 Temperature Assignment
2800
Meter #1 Pressure Assignment
2801
Meter #1 Density Assignment
2802
Meter #1 Dens.Temperature Assignment
2803
Meter #1 Dens.Pressure Assignment
2804
Meter #2 BS&W Assignment
2805
Meter #2 Temperature Assignment
2806
Meter #2 Pressure Assignment
2807
Meter #2 Density Assignment
2808
Meter #2 Dens.Temperature Assignment
2809
Meter #2 Dens.Pressure Assignment
2810
Spare #1 Assignment
2811
Spare #2 Assignment
2841-2844
Analog Input #1 TAG ID
8 Chars.
2845-2848
Analog Input #2 TAG ID
8 Chars.
2849-2852
Analog Input #3 TAG ID
8 Chars.
2853-2856
Analog Input #4 TAG ID
8 Chars.
2857-2860
RTD #1 TAG ID
8 Chars.
2861-2864
RTD #2 TAG ID
8 Chars
2865-2866
Analog Output #1 TAG ID
8 Chars
2867-2870
Analog Output #2 TAG ID
8 Chars
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...