Dynamic Flow Computers
SFC332L Manual
Modbus Data
– 4-35
Modbus Address Table
– 32 Bits
ADDRESS DESCRIPTION
DECIMAL READ/WRITE
Date: 8/1/2019
*Note
: no of decimal position is contengined on the resolution setting.
Flow Resolution (meter#1- 2638, meter#2
– 2644)
Temperature Resolution (2794)
Pressure Reslution (2795)
Current Data Area
9001
Meter #1 Calculation Type Flag
0 Inferred
Read
9003
Meter #1 Flow Flag/Flow Dir
0 Inferred
Read
Flow Direction B0-B3 : 1:Reverse, 0:Forward
Flow Flag B4-B7 : 1:Meter#1 Bi-Dir,2:Meter#2 Bi-Dir,3:Meter#1/#2 Bi-Dir
9005
Meter #1 Alarm Status Flag
0 Inferred
Read
9007
Meter #1 Forward Batch GROSS
0,1,2 Inferred*
Read
9009
Meter #1 Forward Batch NET
0,1,2 Inferred*
Read
9011
Meter #1 Forward Batch MASS
1,2,3 Inferred*
Read
9013
Spare
9015
Meter #1 Forward FWA DP
4 Inferred
Read
9017
Meter #1 Forward FWA Temperature
0,1,2 Inferred*
Read
9019
Meter #1 Forward FWA Pressure
0,1 Inferred*
Read
9021
Meter #1 Forward FWA Density LB/FT3
3 Inferred
Read
9023
Meter #1 Forward FWA Dens.Temperature
2 Inferred
Read
9025
Meter #1 Forward FWA LB/FT3.b
3 Inferred
Read
9027
Meter #1 Forward FWA Y Factor
6 Inferred
Read
9029
Meter #1 Forward FWA Fa Factor
6 Inferred
Read
9031
Meter #1 Forward FWA K/CD/MF Factor
6 Inferred
Read
9033
Meter #1 Forward FWA CTL
4 Inferred
Read
9035
Meter #1 Forward FWA CPL
4 Inferred
Read
9037
Meter #1 GROSS Flowrate
0,1,2 Inferred*
Read
9039
Meter #1 NET Flowrate
0,1,2 Inferred*
Read
9041
Meter #1 MASS Flowrate
3 Inferred
Read
9043
Spare
9045
Meter #1 DP
4 Inferred
Read
9047
Meter #1 Temperature
0,1,2 Inferred*
Read
9049
Meter #1 Pressure
0,1 Inferred*
Read
9051
Meter #1 Density LB/FT3
3 Inferred
Read
9053
Meter #1 Densitometer Temperature
0,1,2 Inferred*
Read
9055
Meter #1 LB/FT3.b
3 Inferred
Read
9057
Meter #1 Y Factor
6 Inferred
Read
9059
Meter #1 Fa Factor
6 Inferred
Read
9061
Meter #1 K/CD/LMF Factor
6 Inferred
Read
9063
Meter #1 GM/CC
6 Inferred
Read
9065
Meter #1 CTL Factor
4 Inferred
Read
9067
Meter #1 CPL Factor
4 Inferred
Read
9069
Meter #1 Equilibrium Pressure
3 Inferred
Read
9071
Meter #1 API
1 Inferred
Read
9073
Meter #1 SG
4 Inferred
Read
9075
Meter #1 Reverse Batch GROSS
0,1,2 Inferred*
Read
9077
Meter #1 Reverse Batch NET
0,1,2 Inferred*
Read
9079
Meter #1 Reverse Batch MASS
1,2,3 Inferred*
Read
9081
Spare
9083
Meter #1 Reverse FWA DP
4 Inferred
Read
9085
Meter #1 Reverse FWA Temperature
0,1,2 Inferred*
Read
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...