Dynamic Flow Computers
SFC332L Manual
Modbus Data
– 4-18
Modbus Address Table
– 32 Bits
ADDRESS DESCRIPTION
DECIMAL READ/WRITE
Date: 8/1/2019
*Note
: no of decimal position is contengined on the resolution setting.
Flow Resolution (meter#1- 2638, meter#2
– 2644)
Temperature Resolution (2794)
Pressure Reslution (2795)
3713-3719
Spare
3721
Meter#1 Yesterday’s Forward Daily Gross Total
1 Inferred
Read
3723
Meter#1 Yesterday’s Forward Daily Net Total
1 Inferred
Read
3725
Meter#1 Yesterday’s Forward Daily Mass Total
2 Inferred
Read
3727
Meter#2 Yesterday’s Forward Daily Gross Total
1 Inferred
Read
3729
Meter#2 Yesterday’s Forward Daily Net Total
1 Inferred
Read
3731
Meter#2 Yesterday’s Forward Daily Mass Total
2 Inferred
Read
3733
Station Yesterday’s Forward Daily Gross Total
1 Inferred
Read
3735
Station Yesterday’s Forward Daily Net Total
1 Inferred
Read
3737
Station Yesterday’s Forward Daily Mass Total
2 Inferred
Read
3739
Spare
3741
Meter #1 Calibration Mass Flowrate
3 Inferred
Read
3743
Meter #2 Calibration Mass Flowrate
3 Inferred
Read
3745-3789
Spare
3791
Meter #1 Temperature Override
2 Inferred
Read/Write
3793
Meter #2 Temperature Override
2 Inferred
Read/Write
3795
Meter #1 Pressure Override
1 Inferred
Read/Write
3797
Meter #1 Pressure Override
1 Inferred
Read/Write
3799
Meter #1 Gravity Override
1 or 4 Inferred
Read/Write
3801
Meter #1 Alpha T E-6 Override
1 Inferred
Read/Write
3803
Meter #2 Gravity Override
1 or 4 Inferred
Read/Write
3805
Meter #2 Alpha T E-6 Override
1 Inferred
Read/Write
3807
Equilibrium Pressure Override #1
3 Inferred
Read/Write
3809
Equilibrium Pressure Override #2
3 Inferred
Read/Write
3811
Request Start Date
0 Inferred
Read/Write
3813-4149 Reserved
4151
Meter #1 Densitometer Period
3 Inferred
Read
4153
Meter #2 Densitometer Period
3 Inferred
Read
4155-4199
Spare
4201
Date (MMDDYY)
0 Inferred
Read/Write
4203
Time (HHMMSS)
0 Inferred
Read/Write
4205
Meter #1 Preset Volume
0,1,2 Inferred*
Read/Write
4207
Meter #1 Preset Warning
0,1,2 Inferred*
Read/Write
4209
Meter #2 Preset Volume
0,1,2 Inferred*
Read/Write
4211
Meter #2 Preset Warning Volume
0,1,2 Inferred*
Read/Write
4213
Meter #1 DP Cut Off
4 Inferred
Read/Write
4215
Meter #1 Flow Low Limit
3 Inferred
Read/Write
4217
Meter #1 Flow High Limit
3 Inferred
Read/Write
4219
Meter #1 Batch Number
0 Inferred
Read/Write
4221
Meter #1 Next Batch Preset Volume
0,1,2 Inferred*
Read/Write
4223
Meter #1 Next Batch Preset Warning
0,1,2 Inferred*
Read/Write
4225
Meter #2 DP Cut Off
4 Inferred
Read/Write
4227
Meter #2 Flow Low Limit
3 Inferred
Read/Write
4229
Meter #2 Flow High Limit
3 Inferred
Read/Write
4231
Meter #2 Batch Number
0 Inferred
Read/Write
4233
Meter #2 Next Batch Preset Volume
0,1,2 Inferred*
Read/Write
4235
Meter #2 Next Batch Preset Warning
0,1,2 Inferred*
Read/Write
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...