Dynamic Flow Computers
SFC332L Manual
Modbus Data
– 4-13
Modbus Address Table
– 32 Bits
ADDRESS DESCRIPTION
DECIMAL READ/WRITE
Date: 8/1/2019
*Note
: no of decimal position is contengined on the resolution setting.
Flow Resolution (meter#1- 2638, meter#2
– 2644)
Temperature Resolution (2794)
Pressure Reslution (2795)
3225
Meter #2 Gross Flowrate
0,1,2 Inferred*
Read
3227
Meter #2 NET Flowrate
0,1,2 Inferred*
Read
3229
Meter #2 MASS Flowrate
3 Inferred
Read
3231
Spare
3233
Meter #2 DP Low
4 Inferred
Read
3235
Meter #2 DP High
4 Inferred
Read
3237
Meter #2 DP
4 Inferred
Read
3239
Meter #2 Temperature
0,1,2 Inferred*
Read
3241
Meter #2 Pressure
0,1 Inferred*
Read
3243
Meter #2 Density
3 Inferred
Read
3245
Meter #2 Density Temperature
0,1,2 Inferred*
Read
3247
Meter #2 Density@60
3 Inferred
Read
3249
Meter #2 Y Factor
6 Inferred
Read
3251
Meter #2 Fa Factor
6 Inferred
Read
3253
Meter #2 K/CD/MF Factor
6 Inferred
Read
3255
Spare
3257
Meter #2 CTL
4 Inferred
Read
3259
Meter #2 CPL
4 Inferred
Read
3261
Meter #2 EQUIL
3 Inferred
Read
3263
Meter #2 API
1 Inferred
Read
3265
Meter #2 SG
4 Inferred
Read
3267
Meter #2 Forward Batch GROSS Total
0,1,2 Inferred*
Read
3269
Meter #2 Forward Batch NET Total
0,1,2 Inferred*
Read
3271
Meter #2 Forward Batch MASS Total
1,2,3 Inferred*
Read
3273
Spare
3275
Meter #2 Forward Cum. GROSS Total
0,1,2 Inferred*
Read
3277
Meter #2 Forward Cum. NET Total
0,1,2 Inferred*
Read
3279
Meter #2 Forward Cum. MASS Total
1,2,3 Inferred*
Read
3281
Spare
3283
Meter #2 Reverse Batch GROSS Total
0,1,2 Inferred*
Read
3285
Meter #2 Reverse Batch NET Total
0,1,2 Inferred*
Read
3287
Meter #2 Reverse Batch MASS Total
1,2,3 Inferred*
Read
3289
Spare
3291
Meter #2 Reverse Cum. GROSS Total
0,1,2 Inferred*
Read
3293
Meter #2 Reverse Cum. NET Total
0,1,2 Inferred*
Read
3295
Meter #2 Reverse Cum. MASS Total
1,2,3 Inferred*
Read
3297
Spare
3299
Meter #2 Batch Number
0 Inferred
Read
3301
Meter #2 Batch Start Date
0 Inferred
Read
3303
Meter #2 Batch Start Time
0 Inferred
Read
3305-3317 Spare
3319
Station GROSS. Flowrate
0,1,2 Inferred*
Read
3321
Station NET Flowrate
0,1,2 Inferred*
Read
3323
Station MASS Flowrate
3 Inferred
Read
3325
Spare
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...