Dynamic Flow Computers
SFC332L Manual
Data Entry
— 2-10
Date: 8/1/2019
W
E D G E
M
E T E R
D
A T A
To set Wedge meter flow parameters, |
Flow Equation Type = 2,
and click “eq. settings”
button
.
You will then access a submenu in which you can set the parameters below.
Pipe I.D. Inches
Orifice ID Inches
Pipe ID in inches is the measured inside pipe diameter to 5 decimals at reference conditions. Orifice ID in
inches is the measured diameter of the orifice at reference conditions.
DP Cutoff
The SFC332L Flow Computer suspends all calculations whenever the DP, in inches of water column, is
less than this value. This function is vital for suppressing extraneous data when the DP transmitter drifts
around the zero mark under no-flow conditions.
Flow Coefficient Kd2 and Expansion Factor - FA
wedge
of
t
coefficien
Discharge
wedge
of
t
coefficien
Expansion
conditions
flow
at
gravity
specific
liquid
d2
K
a
F
SG
DP
(GPM)
Rate
Flow
water
of
inches
pressure,
al
differenti
SG
DP
)
d
x K
a
x F
.
(
2
668
5