Dynamic Flow Computers
SFC332L Manual
Data Entry
— 2-16
Date: 8/1/2019
For this Product
Use this Table
Under these
Conditions
Crude oil, natural gasoline, drip gasoline
6A,24A
Density is known
Crude oil, natural gasoline, drip gasoline
5A/6A,23A/24A
Live densitometer used
Gasoline, naphthalene, jet fuel, aviation fuel,
kerosene, diesel, heating oil, furnace oil
5B/6B,23B/24B
live density is used
Gasoline, naphthalene, jet fuel, aviation fuel,
kerosene, diesel, heating oil, furnace oil
6B,24B
No live density is used
Benzene, toluene, styrene,
ortho
-xylene,
meta
-
xylene, acetone
6C/24C
All conditions
LPG
OLD 23/24
live density is used
LPG
OLD 24
Density is known
LPG
New 23/24
All conditions
ASTM1550A/B
live density is used
ASTM1550B
Density is known
Mixture Property
NIST14
All conditions
PPMix
PPMIX
Live density is used
When Ethylene-API2565-NBS1045 is selected and API2565 is out of range, NBS 1045 is used for
calculations.
Light products: GPA15 is used to calculate vapor pressure. Pressure correction is performed per Ch.
11.2.1, Ch. 11.22.
This Parameter is Required
For These Tables
API Gravity at 60 Deg.F
1, 3, 11
Specific Gravity at 60 Deg.F
5, 7, 9, 10, 14
Density at 60 Deg.F
12, 13, 15, 16, 17
Alpha T E-6
10, 11
Alpha T E-6
The Alpha T will be prompted only if table 6C or 24C is selected. Enter Alpha T value, the number entered
will be divided by 10
-6
.
Example: Entered Value 335 (Actual value 0.000335)
Summary of Contents for SFC332L
Page 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Page 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Page 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Page 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Page 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...