Operation
Operating Instructions 878-M PREMIUM - 06.0 - 11/2021
22
Fig. 4: Inserting and replacing the needle - 2-needles machine
1. Turn the handwheel until the needle bar (1) reaches the upper
end position.
2. Loosen the screws (2).
3. Pull the needle out towards the bottom.
4. Insert the new needle.
5.
Important:
Align the needles so that the groove (3)
is facing the hook according to section (4) or (5). The needles
may not be oriented as shown at section (6).
6. Tighten the screws (2).
(1) - Needle bar
(2) - Screws
(3) - Groove
(4), (5), (6) - Orientation of needle
②
①
③
④
⑤
⑥
max. 3
°