![Dürkopp Adler 878-160722-M Operating Instructions Manual Download Page 106](http://html1.mh-extra.com/html/durkopp-adler/878-160722-m/878-160722-m_operating-instructions-manual_2542290106.webp)
104
Operating Instructions 878-M PREMIUM - 06.0 - 11/2021
6.5.3.4 Setting the
Outputs (Output)
parameter
This parameter provides virtual outputs that can be assigned cus-
tomer-specific functions. They can be used when customer-specific
applications require a signal from the control of the machine.
This parameter cannot be used unless the virtual outputs have been
assigned to a physical output at the Technician level. This requires
that the parameter
Additional I/O Configuration
can be
configured at the Technician level; for more details, refer to the
explanation in the
Service Instructions
.
6.5.4
Setting the
Segment Begin
parameters
There are various options for setting the Segment Begin param-
eters. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Icon
Parameter
Settings
Parameter Seam Begin
Needle thread clamp
The needle thread clamp is closed at
the 1
st
stitch of the seam to ensure that
the needle thread lies on the underside
of the sewing material.
Value range
On/Off
Seam begin bartack parameters
Bartack at seam begin
Value range
On/Off
Number of stitches backwards
Value range
01 to 50
Number of stitches forward
Value range
01 to 50
Summary of Contents for 878-160722-M
Page 1: ...878 M PREMIUM Operating Instructions...
Page 6: ...Obsah 4 Operating Instructions 878 M PREMIUM 06 0 11 2021...
Page 14: ...Safety Operating Instructions 878 M PREMIUM 06 0 11 2021 12...
Page 146: ...144 Operating Instructions 878 M PREMIUM 06 0 11 2021...
Page 174: ...Disposal 172 Operating Instructions 878 M PREMIUM 06 0 11 2021...
Page 178: ...Appendix 176 Operating Instructions 878 M PREMIUM 06 0 11 2021 10 3Interconnection diagram...
Page 179: ......