8.13 Electrical connection
8.13.1 Checking the mains voltage
Important:
The voltage on the type plate of the sewing drive must
correspond to the mains voltage.
1. Check the mains voltage before connecting the machine.
8.13.2 Fitting and connecting the sewing lamp and
sewing lamp transformer
DANGER
Risk of death from electric shock!
The machine may only be connected by trained
electricians.
Disconnect the power plug before carrying out
work on the electrical equipment.
Make sure the power plug cannot be accidentally
plugged back in.
The voltage on the type plate of the sewing drive
must correspond to the mains voltage.
DANGER
Risk of death from electric shock!
When you disconnect the sewing machine from
the power supply at the main switch, the supply
voltage for the sewing lamp remains active.
Pull out the power plug before fitting and
connecting the sewing lamp and sewing lamp
transformer.
Make sure the power plug cannot be accidentally
plugged back in.
Summary of Contents for 878-160722-M
Page 1: ...878 M PREMIUM Operating Instructions...
Page 6: ...Obsah 4 Operating Instructions 878 M PREMIUM 06 0 11 2021...
Page 14: ...Safety Operating Instructions 878 M PREMIUM 06 0 11 2021 12...
Page 146: ...144 Operating Instructions 878 M PREMIUM 06 0 11 2021...
Page 174: ...Disposal 172 Operating Instructions 878 M PREMIUM 06 0 11 2021...
Page 178: ...Appendix 176 Operating Instructions 878 M PREMIUM 06 0 11 2021 10 3Interconnection diagram...
Page 179: ......