Maintenance
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
91
Water condensation will accumulate in the water separator (2) of
the compressed air maintenance unit.
Proper setting
Water condensation must not rise up to the level of the filter
element (1).
Check the water level in the water separator (2) on a daily basis.
Fig. 52: Draining the water condensation
Drain water condensation as follows:
1.
Disconnect the machine from the compressed air supply.
2.
Place the collection tray under the drain screw (3).
3.
Disconnect the connection hose from the compressed air
supply.
4.
Unscrew the drain screw (3) completely.
5.
Allow water to drain into the collection tray.
6.
Re-tighten the drain screw (3).
7.
Connect the machine to the compressed air supply.
(1) - Filter element
(2) - Water separator
(3) - Drain screw
①
②
③