'Crane Commander' Series
Thank you for purchasing this Drivecon 'Crane Commander' variable frequency AC motor drive.
NOTE: Please read and understand this manual before operating the inverter.
DANGER: Make sure all sources of power are removed from inverter and internal capacitors
are discharged or personal injury may result.
This will ensure safe and reliable operation of the inverter.
Quick setup and operation procedure.
Warning: Insure only qualified personnel install and operate this inverter. Installation must
comply with NEC, CMAA and all appropriate local codes.
1.
Connections:
AC mains power L1, L2, and L3 at TM1
Motor connections T1, T2, and T3 at TM1
Control wiring - Terminal strip TM2 - note numbering on page 11 and 12.
Select either keypad or remote terminal strip operation.
2.
Keypad operation
The following functions must be set after loading the 'Quick-load' feature. This is used only
to verify operation. Not suited for normal operation.
Fn29=0
for hoist
Fn29= 1
for
traverse operation and then set
Fn10
,
Fn11 = 0
and
Fn25
= set operating frequency desired.
NOTE: Forward run and reverse run are limited to momentary operation only for increased
safety.
3.
Remote input operation
Install forward, reverse, speed reference and other connections to terminal strips TM2 for
24VDC connections or TB1 of D61530 for 120VAC connections - refer to interconnection
diagram on page 11 and 12.
The following functions will be set using the 'Quick-load' feature:
Fn29=0
for hoist
Fn29= 1
for traverse operation.
Fn10=1
,
Fn11
= as required for speed control method, default =2 (preset steps)
4.
CAUTION:
The Crane Commander is equipped with the 'Quick-Set'
TM
function. These
pre-set parameters are tailored for either hoists or traverse motions. They are general
setpoints and not considered the final setpoints. Please consult the manual and program the
drives with specific parameters which maximize function and safety of the equipment.
5.
CAUTION:
When connecting a potentiometer to terminals 12, 13, and 14 this should be in
strict compliance with wiring detail on page 11 and 12. Incorrect wiring will damage the
inverter.
6.
CAUTION: Control supply voltage
On CC-4110, CC-4150 and CC-4220 set the supply voltage by removing the front cover and
repositioning the link on the supply PCB. A caution label indicates this must be done
prior to operation of the inverter. Normal setting is 460VAC. Do not change if 460V
corresponds with your supply.
THE ABOVE ARE MINIMUM SETTINGS REQUIRED TO OPERATE THE INVERTER. MANY OTHER
OPERATING FEATURES ARE AVAILABLE AND ARE DETAILED IN THIS MANUAL. IT IS STRONGLY
RECOMMENDED THAT THIS MANUAL BE READ AND UNDERSTOOD TO OBTAIN OPTIMUM PER-
FORMANCE FROM YOUR INVERTER. SHOULD ANY QUESTIONS EXIST PLEASE FEEL FREE TO
CONTACT DRIVECON CORPORATION AT (847) 855-9150.