Key Operation
Description
Digital Operator
Display
1
PRGM
(Fn)
*Enter program mode
*Display the current function
code
)Q
2
or keys
*Press up or down keys to select
the desired function code.
)Q
3
READ
ENTER
*Display the current function
parameter.
*DATA lamp light
4
or keys
*Press up or down keys to
change the displayed function
parameter data.
5
READ
ENTER
*Press READ/ENTER to save
the displayed function parameter
into memory.
*DATA lamp goes out
*Digital operator displays the
current frequency.
(QG
;;;;
6
Repeat steps 1-5
*Changing another function
parameter.
7
STOP
*Function parameter setting
procedure ends.
*Enter stopping mode.
*Digital operator displays the
current frequency.
;;;;
35
5.2
Function Parameter Setting (effective in program mode)
5.2.1 Changing the Function Parameters
0.5 sec.
Hz
DATA
DATA
Hz
∧ ∨
∧ ∨
indicates blinking display.
Note:
XXXX
displays the current frequency set at
Fn24
(jog),
Fn25
(normal),
Fn11=0
, and
Fn11=1
(analog input terminal 12-14), or setting of speed at
Fn17
(
Fn11
=2, 3, 4) Displayed value depends on
which frequency mode is in use. The display of the digital operator will blink with the current
frequency setting.
Table 5.2a Changing Function Parameters