Terminal Function List
Terminal
number
Terminal name
Function and Description
TM1
L1/L2/L3
(R,S,T)
Input terminal
CC-200: 1 phase/3 phase, 200-/- 10%
CC1-200: 3phase, 200-/- 10%
50/60 Hz +/- 5%
CC-400: 3 phase, 380-/- 10%
50/60 Hz +/- 5%
T1/T2/T3
(U/V/W)
Output terminal
CC-200: 3 phase, 200-230VAC
CC-200: 3 phase, 200-230VAC
CC-400: 3 phase, 380-460VAC
P/R
External braking
resistor terminal
For external braking resistor
E
Ground terminal
Earth Ground
TM2
1/2
Fault relay
1a fault relay (250VAC/1A, 30VDC/1A)
3
Forward
Forward command
4
Common
Control signal common terminal
5/6
Speed mode
Speed control mode
7
Multi-function #1
Programmable multi-functions
8
Reverse
Reverse command
9
Common
terminal
Common only for terminal 10
10
Programmable
Output signal
Output at "run", "synchronous" mode or when inverter reaches
any
preset frequency.
11
Multi-function #2
Programmable multi-functions
12
Frequency
command
potentiometer
positive
Positive terminal of 10K ohm frequency command potentiometer.
13
Frequency
command
potentiometer
wiper
Wiper of 10K ohm frequency command potentiometer.
14
Frequency
command
potentiometer
negative
Negative terminal of 10K ohm frequency command
potentiometer.
15/16
Frequency meter
output
Drive of remote analog frequency meter. 0-10VDC
Jumper 1
Frequency signal
switch
Select remote frequency control signal
TB1
F
120VAC (24VAC)
forward
Forward command
R
120VAC (24VAC)
reverse
Reverse command
2
120VAC (24VAC)
2nd (hold)
2nd speed or hold function
3
120VAC (24VAC)
3rd (ramp)
3rd speed or ramp up function
4
120VAC (24VAC)
multi-function #1
Multi-function input #1
5
120VAC (24VAC)
multi-function #2
Multi-function input #2
ACN
120V (24VAC)
neutral
AC line neutral
RLA, RLB, RLC
Output relay
Output relay terminals
80
Appendix D
Terminal Function List