45
Fig. 5.3h
Jog frequency output
REV key
(momentary)
FWD key
(momentary)
JOG lamp
JOG key
Fig. 5.3m Jog operation in digital operator control
Fn24:
Jog Frequency Reference (0-180Hz)
Fig. 5.3k
Fig. 5.3l
Fn22:
'Smooth operator' curve time 1 (acceleration)
Fn23:
'Smooth operator' curve time 2 (deceleration)
Smooth transition to ramp conditions for minimal load swing.
Fig. 5.3j 120VAC connection to TB1 of D61530
24VAC connection to TB1 of D61531
NOTE:
Final stopping mode is
determined by setting of Fn53 and
Fn54 for either coast, ramp to stop
or ramp to stop and DC injection
braking.
Fig. 5.3i 24VDC connection to TM2