10
2.5
Common Specifications
Model
CC-204
CC-207
CC-215
CC-222
CC-237
CC-255
CC-275
CC-2110
CC-2150
CC-2220
Constant torque
motor rating (HP)(1)
0.5
1
2
3
5
7.5
10
15
20
30
Constant torque
rated current (A)(2)
3.1
4.5
7.5
10.5
17.5
26.0
35.0
52.0
70.0
105.0
Rated output
(KVA)
1.2
1.7
2.9
4.2
7.0
10.3
13.9
20.0
28.0
41.7
Weight (Lbs)
4.8
4.8
4.8
12.1
12.8
20.7
22
42.9
47.3
49.5
Input voltage
SINGLE PHASE ( Below 3HP) or 3 PHASE, 200~/- 10%, 50~60 Hz +/- 5%
Output voltage
3 PHASE, 0~200~230VAC
Model
CC-404
CC-407
CC-415
CC-422
CC-437
CC-455
CC-475
CC-4110
CC-4150
CC-4220
Constant torque
motor rating (HP)(1)
0.5
1
2
3
5
7.5
10
15
20
30
Constant torque
rated current (A)(1)
1.5
2.3
3.8
5.2
8.8
13.0
17.5
26.0
35.0
52.0
Rated output
(KVA)
1.2
1.7
2.9
4.2
7.0
10.3
13.9
20.0
28.0
41.7
Weight (Lbs)
9.2
9.2
9.2
9.2
18.5
22.0
22.0
45.1
47.3
49.5
Input voltage
3 PHASE, 380~/- 10%, 50~60Hz +/- 5%
Output voltage
3 PHASE, 0~380~460VAC
Control mode
Sine Coded PWM Control
F
R
E
Q
U
E
N
C
Y
Accuracy
+/- 0.5% (-10°C~40°C)
Resolution
0.1 Hz
Range
1~180 Hz
Start freq.
1 Hz
Adjustment
Programmed speed presets, infinitely variable,(ramp and hold), external variable resistor 10K ohm; 1~5 VDC, 4~20mADC, 0~10VDC, menu
selectable.
Multi-speed
Programmed speed presets 2-5 Steps (0-180 Hz)
Upper limit
Programmable from 1~180 Hz
Lower limit
Programmable from 0~180 Hz
Accel / Decel time
0.1~800 sec. accel, 1-30 sec. decel. independently programmable dual set points
JOG Frequency
Programmable from 1-180 Hz operationable from keypad pushbutton.
Operation modes
Remote 120V terminal input or keypad FWD/REV momentary.
V/F Pattern
15 pre-defined patterns, One Curve programmable
Braking torque
< or equal to 10HP; 100% with external D.B. resistor. > 10HP D.B. is optional.
DC Braking
injection
Programmable 0.1 - 25.5 sec.; operation level 0 Hz-10Hz; Brake level 0-20%.
Alarm signal
Fault Relay (250V / 1 Amp) Programmable NO or NC
Multi-function O/P
Relay (250V / 1 Amp) Programmable for run mode, up to speed, at setting.
Frequency signal
0~10VDC, Digital Meter. 1mA Full scale moving coil meter
Stop mode
Decelerate or Free Run to Stop Software Selectable
Reset
Closed Contact Point or Pressing RESET on programming console
Display
4 Digits 7 Segments LED's & Status LED 1/2" high red digits.
Protection
22 total; Over Current, Over Voltage, Overtemperature, P.B. sequence error, travel limit,
Low Voltage, Stall Prevention, Ground Fault Protection, Microprocessor error, elapsed timer.
D.B. voltage
385 VDC on, 379 VDC off (200 series); 770 VDC on, 760 VDC off (400 series)
Communication
RS232 standard RS485 (32 units maximum) optional.
Overload
150% for 2 minutes
Overcurrent
200% peak trip
Transient power
failure
Over 15 msec.
Operation
temperature
-10~+40°C +50°C chassis type enclosure.
Humidity
0~95% non-condensing
Vibration
below 0.5G
Environment
Dust free, dry, non-corrosive
(1)
All horsepower data based on standard 4 pole motors.
(2)
Horsepower and current ratings are based on CMAA class A-D use for traverse or hoist
operation with a mechanical load brake. Consult Drivecon for other service classes.
NOTE:
Always size inverters based on the peak amp draw of the motor.
Table 2.5a CC Series Specifications