4.10.1 Sequence Tests
Table 4–4 Sequence Tests
No.
Test Name
Description
1
Poweron
Checks all digital data paths and normal machine
operation. This test runs the same sequence of TESTS
as when initiated by an actual power on, but does NOT do
all operations (see below).
Sequence Order:
3 - Controller Test
40 - Power Supply Test
– - Motor Connection Test (no number)
5 - Initialize Mechanism
46 - Board Configuration
– - Restore (if needed). If power failed in the middle
of a move, the autochanger tries a ‘‘restore’’ of the
last move. The autochanger tries to put the cartridge
back to where it came from. This attempt could fail
(Poweron sequence would fail). POWERON ONLY.
10 - Initialize Element Status (if needed).
38 ‘‘Light Show’’ in the indicators of the control panel.
– - Mailslot rotation (if not secured). This rotation
could fail(Poweron sequence would fail). POWERON
ONLY.
2
Wellness Test
Checks out the general capability of the autochanger.
Needs one loaded cartridge; drives and mailslot empty.
(continued on next page)
4–34 Troubleshooting and Diagnostics