Figure A–1 System Error Report
V A X / V M S SYSTEM ERROR REPORT COMPILED 8−APR−1993 15:11:43
PAGE 1.
******************************* ENTRY 9. *******************************
ERROR SEQUENCE 6552. LOGGED ON: SID 0A000005
DATE/TIME 8−APR−1993 15:10:09.37 SYS_TYPE 04010102
SYSTEM UPTIME: 5 DAYS 21:14:31
SCS NODE: KAWA VAX/VMS V5.4−2
DEVICE ERROR KA420 CPU FW REV# 6.
GENERIC DK SUB−SYSTEM, UNIT _KAWA$WDB300:
HW REVISION 00A50015
HW REVISION = ..¥.
ERROR TYPE 05
EXTENDED SENSE DATA RECEIVED
SCSI ID 03
SCSI ID = 3.
SCSI LUN 00
SCSI LUN = 0.
SCSI SUBLUN 00
SCSI SUBLUN = 0.
PORT STATUS 00000054
%SYSTEM−F−CTRLERR, FATAL CONTROLLER
ERROR
SCSI CMD 00000003
0078
REQUEST SENSE
SCSI STATUS 00
GOOD
EXTENDED SENSE DATA
EXTENDED SENSE 000B0070
0A000000
00000000
0000004E
00A50000
1A000000
00000100
07030000
00
ABORTED COMMAND
SENSE CODE = 4E(X)
UCB$B_ERTCNT 03
3. RETRIES REMAINING
UCB$B_ERTMAX 03
3. RETRIES ALLOWABLE
ORB$L_OWNER 00000000
OWNER UIC [000,000]
UCB$L_CHAR 1CC54008
DIRECTORY STRUCTURED
FILE ORIENTED
SHARABLE
AVAILABLE
ERROR LOGGING
ALLOCATED
CAPABLE OF INPUT
SCSI Command Code
Internal Device Code (15h = 21d)
1st Byte of Extended Sense
Byte 12
Extended Sense Data Sense Key 0Bh
SCSI Command Packet
Sense Key
Additional Sense
Code (ASC) 4Eh =
Bus Protocol Error
A–2 Offline Diagnostic Information
Summary of Contents for RW504-ZA
Page 10: ......
Page 42: ......
Page 58: ......
Page 106: ......
Page 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Page 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Page 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Page 148: ......
Page 206: ......
Page 210: ......
Page 219: ...Voltage Configuration 2 10 Index 5 ...
Page 220: ......