Table 3–3 (Cont.) Autochanger Configuration Choices
No.
Function
Default
Options
31
Secured Mailslot Rotation
(security code required)
Off
Off - Normal mailslot operation.
On - The mailslot rotates in when
configuration 15 is set to ON or a
Prevent Media Removal command
is received. The mailslot remains
closed until configuration 15 is
set to OFF or an Allow Media
Removal command is received.
If the autochanger is full, the
mailslot will open only for an
EJECT command.
32
Mailslot Rotation Command
(security code required)
Off
Off - Normal mailslot operation. If
the host sends a Rotate mailslot
command and config. 32 is set to
off, the host will receive a Check
Condition followed by a Sense Key
of Illegal Request.
On - When a Rotate Mailslot
command is received (either from
the host or via the control panel),
the mailslot is toggled open or
closed.
40
DEC/OEM Mode
Off
Off - Changes inquiry mode to DEC
mode. Required when connected
to a DEC computer to ensure
integrity. This changes default of
Autocontroller PCA.
ON - For use with OEM computers
(HP).
41
DEC/OEM Mode
Off
Off - Changes inquiry mode to DEC
mode. Required when connected to
a DEC computer to ensure integrity.
This changes default of 1.3 Gbyte
multifunction drive only.
ON - For use with OEM computers
(HP).
(continued on next page)
3–14 Product Operation and Configuration
Summary of Contents for RW504-ZA
Page 10: ......
Page 42: ......
Page 58: ......
Page 106: ......
Page 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Page 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Page 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Page 148: ......
Page 206: ......
Page 210: ......
Page 219: ...Voltage Configuration 2 10 Index 5 ...
Page 220: ......