Table 4–2 Information Logs (INFO Logs)
No.
Log Name
Description
0
Autochanger Error
Log
The autochanger maintains a time-stamped history of
past diagnostic test errors that have occurred within the
autochanger. The error message maintained for each error
indicates the failure and the possible Field Replaceable
Units (FRUs) that may have caused the failure.
Displays as follows:
Err n y - nth error; actual error code
FRU A - suspect FRU #1
FRU B - suspect FRU #2
FRU C - suspect FRU #3
Test n - test that failed
abcdefgh - time stamp
1
Firmware Version
Number
Displays the current autochanger firmware version
number.
2
Element Status
Displays the status (
empty
or
full
) of the selected
autochanger element.
Displays three numbers:
First Number = Element number
0 = picker
1 = drive
10 = mailslot
11 - 26 = storage slots
Second Number = Element type
1 = picker
2 = storage slot
3 = mailslot
4 = drive
Third Number = Data mask
00 = empty
01 = full
3
Software Clock
Displays the current ‘‘count’’ in seconds of the software
clock. (hexadecimal)
4
Drive Load Count
Displays the number of cartridge loads into the drive.
(continued on next page)
4–16 Troubleshooting and Diagnostics
Summary of Contents for RW504-ZA
Page 10: ......
Page 42: ......
Page 58: ......
Page 106: ......
Page 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Page 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Page 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Page 148: ......
Page 206: ......
Page 210: ......
Page 219: ...Voltage Configuration 2 10 Index 5 ...
Page 220: ......