Table 4–3 (Cont.) Recovery Procedures for Specific Hardware Errors
Error Code
(hex.)
Error
Recovery Procedures
POWER SUPPLY ERRORS
33 - 34
Power Supply failed
Visually check the power cables and
connections. Run test 40—Power Supply
Test—verify failure.
DRIVE CONNECT ERRORS
38
Drive not connected
On error code 38 be sure to check:
•
Drive cabling
Good contacts
No cut or exposed wires
•
Drive tray not skewed
Run test 37—Drive Connector Test—verify
failure.
MECHANISM ERRORS
Check carriage/picker for free motion.
The carriage should travel easily along
the rail.
3C
Unspecified failure
Run test 11—Autochanger Mechanism
Exercise Test. On error—go to error code in
this table.
3E
Unspecified servo failure
Run test 11—Autochanger Mechanism
Exercise Test—verify failure.
Check the following assemblies in the
autochanger for loose labels or other
obstructions—picker, mailslot, drive,
and storage slots.
40
Unable to free picker
fingers for carriage
motion
Run test 50—Find Home Sequence—verify
failure.
41
Unable to verify picker
is at home position
Run test 50—Find Home Sequence—verify
failure.
(continued on next page)
4–24 Troubleshooting and Diagnostics
Summary of Contents for RW504-ZA
Page 10: ......
Page 42: ......
Page 58: ......
Page 106: ......
Page 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Page 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Page 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Page 148: ......
Page 206: ......
Page 210: ......
Page 219: ...Voltage Configuration 2 10 Index 5 ...
Page 220: ......