Administration and maintenance tasks
Update firmware
Digi XBee Industrial Gateway
41
Errors
Any errors that occur during the restore process appear in a red banner at the top of the
Backup/Restore
page. Typically, the only reason an error occurs is if a user has modified the backup
file. The following list provides some of the possible error messages.
n
Invalid file contents
: The file contents are not a valid backup format. This may be caused by
invalid XML syntax.
n
Element set_setting has extra content (name)
: The settings group name is not recognized.
n
Element set_setting failed to validate content (name)
: Incorrect value for setting name.
n
Other RCI errors are possible, but are less common.
Update firmware
There are several types of firmware updates for XBee Industrial Gateway:
n
XBee Industrial Gateway operating system
: You can download Gateway operating system
firmware updates for XBee Industrial Gateway from the
. You can then load
the firmware through the
or
You can only upgrade the gateway operating system, not downgrade it, through the web
interface or Remote Manager. The firmware image contains a certificate that is verified before
XBee Industrial Gateway accepts an upgrade.
n
XBee RF module on the gateway
: See
Update the local XBee Industrial Gateway firmware
.
n
XBee RF modules on your local network to be delivered Over the Air (OTA)
: As XBee
networks can involve a large number of nodes, Digi provides a way to schedule automatic XBee
Industrial Gateway firmware updates and manage firmware files. In the XBee Industrial
Gateway web interface, OTA firmware updates are performed from a page linked from the
XBee Configuration page. These firmware updates are supported for XBee ZigBee modules
only. For information on these updates, see
XBee network OTA firmware updates
.
Update firmware from Remote Manager
You can update the firmware from Remote Manager:
n
Update the XBee Industrial Gateway device operating system firmware
n
Update the local XBee Industrial Gateway firmware
n
Update the XBee network node firmware (OTA updates) from Remote Manager
You can also
from Remote Manager.
Update the XBee Industrial Gateway device operating system firmware
To update the XBee Industrial Gateway device operating system firmware:
1. Download the appropriate firmware from
XBee Gateway product support page
. For more
details on firmware filename conventions, see
.
2. Log in to
3. Click the
Device Management
tab.