Configure XBee Industrial Gateway
Configure Remote Manager connectivity settings
Digi XBee Industrial Gateway
110
3. Test the Remote Manager connection to verify whether or not it stopped responding and
should be abandoned. Recovery actions are taken as configured in other settings. The Remote
Manager-registered device and Remote Manager each perform their own independent
monitoring of the Remote Manager connection state (active, idle and missed keep-alives). If
Remote Manager protocol messages or data other than keepalives is exchanged over the
Remote Manager connection, the idle timers that trigger keep-alives are reset, and the
consecutive missed keep-alive counts are cleared to zero.
n
Device send keep-alive interval
: Specifies how frequently the device sends a keep-
alive packet to Remote Manager if the Remote Manager connection is idle. Remote
Manager expects to receive either Remote Manager protocol messages or keep-alive
packets from the device at this interval.
n
Server Send Interval
: Specifies how frequently the Remote Manager-registered device
sends a keep-alive packet to Remote Manager if the Remote Manager connection is
idle. Remote Manager expects to receive either Remote Manager protocol messages or
keep-alive packets from the Remote Manager-registered device at this interval.
n
Maximum consecutive missed keep-alives
: After missing the number of consecutive
expected keep-alives specified by this setting, according to the configured intervals, the
connection is considered lost and is closed by the device and Remote Manager.
Note
The best practice is to set this interval value as long as your application can tolerate to reduce
the amount of data traffic.
Basic connectivity settings
n
Enable Device Cloud Connectivity
(Device Cloud)
Let my XBee Gateway connect to Device Cloud
(web interface):
Enables or disables the connection from XBee Industrial Gateway to the Remote Manager
server. Disable this feature if you have no use for Remote Manager, and want to eliminate any
Remote Manager-related network traffic.
n
Device Cloud Server
(Remote Manager)
Server URL
(web interface):
The value for this setting is generally a Fully Qualified Domain Name (FQDN) pointing to one of
the Remote Manager servers. Obtain this value from your Remote Manager server
administrator. Typically this administrator is Digi. The default value is
.
n
Device Cloud Server Port
(Remote Manager)
Server Port
(web interface):
The network port number for the Remote Manager server. The default value is 3199.