Configure security and authentication
Configure User Access Control
Digi CM User Guide
75
In this screen, the "sun-users" Access group has access to Port, Monitor, and Power, while any other
users (<<Everyone>>) do not have access.
Sniff session
A sniff session enables multiple users to access a single serial port for viewing the data stream.
Anyone who is registered for a sniff session can access a specific serial port — even if someone else is
using the port. The Digi CM unit supports multiple concurrent sniff sessions.
Type of users
Access types
How to permit or restrict
Only specific users have
access "Permitted Users"
Access type is unchecked for
Everyone (meaning All other
users) does not have access
By listing specific users and checking
the access types - (Permitting them
access)
All users have access
except for a few
"Restricted Users"
Everyone has access to
everything by checking the
access types. If an access type
is unchecked, all users are
restricted from that access
type.
By listing users and unchecking the
access type they are restricted from
using
Summary of Contents for Digi CM 16
Page 1: ...User Guide Digi CM 8 port 16 port 32 port and 48 port...
Page 63: ...Digi CM User Guide 63 User administration Administer users 64...
Page 130: ...Power Controller Cascade multiple Digi RPM units Digi CM User Guide 130...