Interfaces
Bridging
Digi Connect IT® 16/48 User Guide
153
Edit the preconfigured ETH2 bridge
Required configuration items
n
Enable or disable the bridge.
n
Modify the devices included in the bridge.
Additional configuration items
n
Enable Spanning Tree Protocol (STP).
To edit the preconfigured
LAN1
bridge:
WebUI
1. Log into the Connect IT 16/48 WebUI as a user with full Admin access rights.
2. On the menu, click
System
. Under
Configuration
, click
Device Configuration
.
The
Configuration
window is displayed.
3. Click
Network
>
Bridges
>
LAN1
.
4. The
LAN1
bridge is enabled by default. To disable, uncheck
Enable
.
5. Modify the list of devices that are a part of the bridge. By default, the
LAN1
bridge includes the
following devices:
n
Ethernet: ETH2
n
Wi-Fi access point: Digi AP (Wi-Fi1)
Note
The MAC address of the bridge is taken from the first available device in the list.
a. To delete a device from the bridge, click the down arrow (
) next to the field label and
select
Delete
.
b. To add a device, for
Add device
, click
and select the
Device
.
6. (Optional) Enable Spanning Tree Protocol (STP).