Central management
Collect device health data and set the sample interval
Digi Connect IT® 16/48 User Guide
642
Collect device health data and set the sample interval
You can enable or disable the collection of device health data to upload to Digi Remote Manager, and
configure the interval between health sample uploads. By default, device health data upload is
enabled, and the health sample interval is set to 60 minutes.
To avoid a situation where several devices are uploading health metrics information to Remote
Manager at the same time, the Connect IT 16/48 device includes a preconfigured randomization of
two minutes for uploading metrics. For example, if
Health sample interval
is set to five minutes, the
metrics will be uploaded to Remote Manager at a random time between five and seven minutes.
To disable the collection of device health data or enable it if it has been disabled, or to change the
health sample interval:
WebUI
1. Log into the Connect IT 16/48 WebUI as a user with full Admin access rights.
2. On the menu, click
System
. Under
Configuration
, click
Device Configuration
.
The
Configuration
window is displayed.
3. Click
Monitoring
>
Device Health
.
Device health data upload is enabled by default. To disable, click to toggle off
Enable Device
Health samples upload
.
4. For
Health sample interval
, select the interval between health sample uploads.
5.
Only report changed values to Digi Remote Manager
is enabled by default.
When enabled:
n
The device only reports device health metrics that have changed health metrics were
last uploaded. This is useful to reduce the bandwidth used to report health metrics.
n
All metrics are uploaded once every hour.
When disabled, all metrics are uploaded every
Health sample interval
.
6. (Optional) Click to expand
Data point tuning
.
Data point tuning options allow to you configure what data are uploaded to the Digi Remote
Manager. All options are enabled by default.