26
About Your System
Plug & Play
Configuration Error
Error encountered in
initializing PCI device;
faulty system board.
Install the NVRAM_CLR
jumper and reboot the
system. See Figure 6-1 for
jumper location. Check for
a BIOS update. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 113. If the problem
persists, see "Getting Help"
on page 127.
Read fault
Requested sector
not found
The operating system
cannot read from the
diskette or hard drive, the
system could not find a
particular sector on the
disk, or the requested sector
is defective.
Replace the diskette.
Ensure that the diskette
and hard-drive cables are
properly connected. See
"Troubleshooting a USB
Device" on page 102 or
"Troubleshooting a Hard
Drive" on page 111 for the
appropriate drive(s)
installed in your system.
Remote
Configuration
update attempt
failed
System could not
implement Remote
Configuration request.
Retry Remote
Configuration.
SATA port 0/1/2
hard disk drive
configuration error
Faulty drive. Parameters
failure.
Ensure that the hard drive
cables are properly
connected. See
"Troubleshooting a Hard
Drive" on page 111.
SATA port 0/1/2
hard disk drive
failure
SATA port 0/1/2
hard disk drive
auto-sensing error
Faulty drive. INT13 call
failure from the drive.
Ensure that the hard drive
cables are properly
connected. See
"Troubleshooting a Hard
Drive" on page 111.
Table 1-4.
System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 26 Thursday, August 30, 2007 3:30 PM
Summary of Contents for PowerEdge R200
Page 9: ...Contents 9 Glossary 165 Index 177 ...
Page 10: ...10 Contents ...
Page 96: ...96 Installing System Components ...
Page 116: ...116 Troubleshooting Your System ...
Page 164: ...164 Getting Help ...
Page 176: ...176 Glossary ...
Page 182: ...182 Index ...