Error: Remote
Access Controller
initialization
failure.
Faulty or improperly
installed RAC.
Ensure that the RAC is
properly installed. See
"Troubleshooting
Expansion Cards" on
page 113.
Error 8602:
Auxiliary device
failure. Verify
that mouse and
keyboard are
securely attached
to correct
connectors.
Loose or improperly
connected mouse or
keyboard cable; faulty
mouse or keyboard.
Replace the mouse. If the
problem persists, replace
the keyboard.
Gate A20 failure
Faulty keyboard controller
(faulty system board).
See "Getting Help" on
page 127.
General failure
The operating system is
unable to carry out the
command.
This message is usually
followed by specific
information. Take the
appropriate action to
resolve the problem.
Keyboard controller
failure
Faulty keyboard controller
(faulty system board).
See "Getting Help" on
page 127.
Keyboard data line
failure
Keyboard failure
Keyboard stuck key
failure
Loose or improperly
connected keyboard cable;
faulty keyboard; faulty
keyboard controller.
Ensure that the keyboard is
properly connected. If the
problem persists, replace
the keyboard. If the
problem persists, see
"Getting Help" on
page 127.
Keyboard fuse has
failed.
Keyboard fuse has failed.
Replace the keyboard.
Faulty system board.
If the problem persists, the
system board is faulty. See
"Getting Help" on
page 127.
Table 1-4.
System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 22 Thursday, August 30, 2007 3:30 PM
Summary of Contents for PowerEdge R200
Page 9: ...Contents 9 Glossary 165 Index 177 ...
Page 10: ...10 Contents ...
Page 96: ...96 Installing System Components ...
Page 116: ...116 Troubleshooting Your System ...
Page 164: ...164 Getting Help ...
Page 176: ...176 Glossary ...
Page 182: ...182 Index ...