Diagnostics Indicator Codes
The four diagnostics indicators on the system front panel display error codes
during system startup. Table 1-5 lists the causes and possible corrective
actions associated with these codes.
Write fault
Write fault on
selected drive
Faulty diskette, diskette
drive, hard drive.
Replace the diskette.
Ensure that the diskette
drive and hard-drive cables
are properly connected. See
"Troubleshooting a USB
Device" on page 102 or
"Troubleshooting a Hard
Drive" on page 111 for the
appropriate drive(s)
installed in your system.
Table 1-5.
Diagnostic Indicator Codes
Code
Causes
Corrective Action
Possible processor
failure.
See "Troubleshooting the
Microprocessor" on page 114.
Memory failure.
See "Troubleshooting System
Memory" on page 108.
Possible expansion
card failure.
See "Troubleshooting Expansion
Cards" on page 113.
Table 1-4.
System Messages
(continued)
Message
Causes
Corrective Actions
A B C D
A B C D
A B C D
= y e l l o w
= g r e e n
= o f f