Table 12: J-SRX100 Services Gateway Cabinet Requirements
(continued)
Specifications
Cabinet
Requirements
•
The cabinet is at least 1 U (1.75 in. or 4.5 cm) high.
•
The outer edges of the mounting brackets extend the width of either chassis
to 19 in. (48.3 cm), and the front of the chassis extends approximately 0.5
in. (1.27 cm) beyond the mounting brackets.
•
The minimum total clearance inside the cabinet is 30.7 in. (78 cm) between
the inside of the front door and the inside of the rear door.
NOTE: The holes for the mounting brackets chassis are spaced 1.25 in. (3.2
cm) apart, measured from the center of the hole.
Clearance
requirements
•
Ensure sufficient ventilation through the cabinet is sufficient to prevent
overheating.
•
Ensure adequate cool air supply to dissipate the thermal output of the
device.
•
Install the device as close as possible to the front of the cabinet so that
the cable management system clears the inside of the front door. Installing
the chassis close to the front of the cabinet maximizes the clearance in
the rear of the cabinet for critical airflow.
•
Route and dress all cables to minimize the blockage of airflow to and from
the chassis.
NOTE: A cabinet larger than the minimum required provides better airflow
and reduces the chance of overheating.
Cabinet airflow
requirements
Related
Documentation
General Site Guidelines for Installing the J-SRX100 Services Gateway on page 22
•
•
J-SRX100 Services Gateway Rack Requirements on page 23
•
Site Preparation Checklist for the J-SRX100 Services Gateway on page 19
•
Clearance Requirements for Airflow and Hardware Maintenance of the J-SRX100
Services Gateway on page 24
J-SRX100 Services Gateway Rack Requirements
The services gateway can be installed in a rack. Many types of racks are acceptable,
including front-mount racks and four-post (telco) racks.
NOTE:
The services gateway cannot be center-mounted in racks.
Table 13 on page 24 provides the details on rack size, clearance, and airflow requirements.
23
Chapter 3: Preparing the Site for J-SRX100 Services Gateway Installation
Summary of Contents for PowerConnect J-SRX100
Page 1: ...Dell PowerConnect J Series J SRX100 Services Gateway Hardware Guide Published 2010 10 28 ...
Page 6: ...vi ...
Page 14: ...xiv PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 16: ...2 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 20: ...6 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 32: ...18 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 44: ...30 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 50: ...36 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 54: ...40 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 64: ...50 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 72: ...58 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 76: ...62 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 98: ...84 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 110: ...96 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 112: ...98 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 136: ...122 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 140: ...126 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 144: ...130 PowerConnect J SRX100 Services Gateway Hardware Guide ...
Page 153: ...PART 5 Index Index on page 141 139 ...
Page 154: ...140 PowerConnect J SRX100 Services Gateway Hardware Guide ...