Specifications: Dell OptiPlex GX1 Small-Form-Factor System User's Guide
file:///C|/infodev/2013/eDoc/OpGX1/UG/specs.htm[2/21/2013 11:47:12 AM]
<Ctrl><Alt><\>
Toggles microprocessor speeds on 101-key keyboard (in MS-DOS® real
mode only)
<Ctrl><Alt><#>
Toggles microprocessor speeds on 102-key keyboard (in MS-DOS real mode
only)
<F2> or
<Ctrl><Alt><Enter>
Starts the System Setup program (during power-on system test [POST] only)
<F3> or <F12>
Automatically starts (boots) the system from the network environment
specified by the Managed Boot Agent (MBA) rather than from one of the
devices in the
System Setup
Boot Sequence
option
<F10>
Launches the utility partition (if installed) during system start-up
Controls and Indicators
Reset control
No reset button on small-form-factor systems
Power control
Push button
Power indicators
Green light-emitting diode (LED) on riser board; blinking green in sleep state;
dual-color LED on front panel—green for power, yellow for diagnostics
Hard-disk drive access
indicator
Green LED
Link integrity indicator (on
NIC connector)
Green LED for 10-Mb operation; orange LED for 100-Mb operation
Activity indicator (on NIC
connector)
Yellow LED
Power
DC power supply:
Wattage
Small-form-factor chassis: 110
Heat dissipation
Small-form-factor chassis: 808 British thermal units (BTU)/hr (nominal)
Voltage
90 to 135 volts (V) at 60 Hz; 180 to 265 V at 50 Hz
Backup battery
3-V CR2032 coin cell
Physical