Messages and Codes: Dell OptiPlex GX1 Small-Form-Factor System User's Guide
file:///C|/infodev/2013/eDoc/OpGX1/UG/messages.htm[2/21/2013 11:47:24 AM]
Table 2. System Beep Codes
Code
Cause
Action
1-1-2
Microprocessor register
failure
See "
Getting Help
" for instructions on obtaining technical assistance.
1-1-3
NVRAM
Run the
System Set Test Group
in the Dell Diagnostics.
1-1-4
ROM BIOS checksum
failure
Run the
System Set Test Group
in the Dell Diagnostics, if possible.
1-2-1
Programmable interval
timer
Run the
System Set Test Group
in the Dell Diagnostics, if possible.
1-2-2
Direct memory access
(DMA) initialization
failure
Run the
System Set Test Group
in the Dell Diagnostics, if possible.
1-2-3
DMA page register
read/write failure
Run the
System Set Test Group
in the Dell Diagnostics, if possible.
1-3
Video Memory Test
failure
Run the
Video Test Group
in the Dell Diagnostics.
1-3-1
through
2-4-4
DIMMs not being
properly identified or
used
See "
Troubleshooting System Memory
."
3-1-1
Slave DMA register
failure
Run the
System Set Test Group
in the Dell Diagnostics, if possible.
3-1-2
Master DMA register
failure
Run the
System Set Test Group
in the Dell Diagnostics, if possible.
3-1-3
Master interrupt mask
register failure
See "
Getting Help
" for instructions on obtaining technical assistance.
3-1-4
Slave interrupt mask
register failure
See "
Getting Help
" for instructions on obtaining technical assistance.
3-2-2
Interrupt vector loading
failure
See "
Getting Help
" for instructions on obtaining technical assistance.
3-2-4
Keyboard Controller
Test failure
Run the
Keyboard Controller Test
in the Dell Diagnostics.
Otherwise, see "
Getting Help
" for instructions on obtaining technical
assistance.
3-3-1
NVRAM power loss
Run the
System Set Test Group
in the Dell Diagnostics, if possible.
3-3-2
NVRAM configuration
Run the
System Set Test Group
in the Dell Diagnostics, if possible.
3-3-4
Video Memory Test
failure
Run the
Video Test Group
in the Dell Diagnostics.
3-4-1
Screen initialization
failure
Run the
Video Test Group
in the Dell Diagnostics.