AV7000 LINEAR CAMERA REFERENCE MANUAL
304
7
e-Genius
Description
Type
Explanation
Possible Cause
Solution
Error: FSM Data Valid
Error
The focus servo
EEPROM is not valid
or is corrupt.
Data corruption while
reading the EEPROM.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: FSM exceeded
max temp
Error
The focus servo
exceeded the
maximum internal
temperature.
Ambient temperature
has exceeded the
maximum 50 degrees C
operating temperature.
There is a fan failure or
airflow blockage.
Verify the ambient
temperature is less than or
equal to 50 C. Check the
fan operation and for any
airflow obstructions.
Replace fans if necessary.
Error: FSM Invalid
Servo command
received
Error
The camera received
an invalid command
response from the
focus servo.
Internal communication
failure.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: FSM Invalid
Servo packet received
Error
The camera received
an invalid data packet
for the command from
the focus servo.
Internal communication
failure.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: FSM PWM Over
Limit
Error
The focus servo
exceeding the
maximum PWM
attempting to get to
the commanded
position.
The shipping lock is still
engaged or partially
engaged. There is an
internal hardware
failure.
Verify the shipping lock is
fully dis-engaged. Cycle the
unit’s power. If the error
persists, replace the camera
and/or contact Datalogic
Support.
Error: FSM PWM Over
Time
Error
The focus servo
exceeding the
maximum PWM
timeouts attempting to
get to the commanded
position.
The shipping lock is still
engaged or partially
engaged. There is an
internal hardware
failure.
Verify the shipping lock is
fully dis-engaged. Cycle the
unit’s power. If the error
persists, replace the camera
and/or contact Datalogic
Support.
Error: FSM Servo
reception
Error
The camera is unable
to receive messages
from the focus servo.
Internal communication
failure.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: FSM Servo
Transmission
Error
The camera is unable
to send messages to
the focus servo.
Internal communication
failure.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: GPIO Handler
stopped responding
Error
The GPIO Handler
application has
stopped.
The application has
stopped responding or
crashed.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: Illumination
exceeded max temp
Error
The illumination
exceeded the
maximum internal
temperature
Ambient temperature
has exceeded the
maximum 50 degrees C
operating temperature.
There is a fan failure or
airflow blockage.
Verify the ambient
temperature is less than or
equal to 50 C. Check the
fan operation and for any
airflow obstructions,
particularly at the ends of the
illumination. Replace fans if
necessary.
Error: Illumination Mon
stopped responding
Error
The Illumination
Monitor application
has stopped.
The application has
stopped responding or
crashed.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: Image Line
Handler stopped
responding
Error
The Image Line
Handler application
has stopped.
The application has
stopped responding or
crashed.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: Image Sensor
Mon stopped
responding
Error
The Sensor Monitor
application has
stopped.
The application has
stopped responding or
crashed.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Error: Interrupt Handler
stopped responding
Error
The Interrupt Handler
application has
stopped.
The application has
stopped responding or
crashed.
Cycle the unit’s power. If the
error persists, replace the
camera and/or contact
Datalogic Support.
Summary of Contents for AV7000
Page 1: ...REFERENCE MANUAL AV7000 Linear Camera...
Page 11: ...xi GENERAL VIEW Figure 2 AV7000 Camera Front View Figure 3 AV7000 Camera Back View...
Page 97: ...ELECTRICAL INSTALLATION 85 3 3 11 7 Powered Outputs Figure 86 Powered Outputs NPN PNP...
Page 107: ...E GENIUS 95 4 Click Show to access Contents Index and Search options...
Page 243: ...IMAGING FEATURES 231 5 Ambient Light Ambient light can influence the signal DC level Good Read...
Page 295: ...IMAGING FEATURES 283 5 Figure 137 140mm Short Lens Reading Linear Barcodes...
Page 296: ...AV7000 LINEAR CAMERA REFERENCE MANUAL 284 5 Figure 138 110mm Lens Reading Linear Barcodes...
Page 297: ...IMAGING FEATURES 285 5 Figure 139 90mm Lens Reading Linear Barcodes...
Page 299: ...IMAGING FEATURES 287 5 Figure 141 140mm Short Lens Reading 2D Barcodes...
Page 300: ...AV7000 LINEAR CAMERA REFERENCE MANUAL 288 5 Figure 142 110mm Lens Reading 2D Barcodes...
Page 301: ...IMAGING FEATURES 289 5 Figure 143 90mm Lens Reading 2D Barcodes...
Page 337: ......