AV7000 LINEAR CAMERA REFERENCE MANUAL
230
5
Other Possible RangeFinder Signal Degradation Factors
Two other factors that can negatively affect the RangeFinder signal are
Laser Power
and
Ambient Light.
Laser Power Test
If the Left (or Right) laser signal looks good, but the opposite side laser code words
periodically drop out:
1. Select left side signal and note its signal amplitude.
NOTE:
The gain may have to be reduced in order to have a good
representation of the signal.
2. Select right side laser and confirm that the signal amplitude is relatively equal to the left
side signal amplitude.
A noticeable discrepancy could indicate a potential problem with the laser diode, and the unit
could report erroneous height data.
Since there are no field repairable items on the RangeFinder the unit should be replaced.
Summary of Contents for AV7000
Page 1: ...REFERENCE MANUAL AV7000 Linear Camera...
Page 11: ...xi GENERAL VIEW Figure 2 AV7000 Camera Front View Figure 3 AV7000 Camera Back View...
Page 97: ...ELECTRICAL INSTALLATION 85 3 3 11 7 Powered Outputs Figure 86 Powered Outputs NPN PNP...
Page 107: ...E GENIUS 95 4 Click Show to access Contents Index and Search options...
Page 243: ...IMAGING FEATURES 231 5 Ambient Light Ambient light can influence the signal DC level Good Read...
Page 295: ...IMAGING FEATURES 283 5 Figure 137 140mm Short Lens Reading Linear Barcodes...
Page 296: ...AV7000 LINEAR CAMERA REFERENCE MANUAL 284 5 Figure 138 110mm Lens Reading Linear Barcodes...
Page 297: ...IMAGING FEATURES 285 5 Figure 139 90mm Lens Reading Linear Barcodes...
Page 299: ...IMAGING FEATURES 287 5 Figure 141 140mm Short Lens Reading 2D Barcodes...
Page 300: ...AV7000 LINEAR CAMERA REFERENCE MANUAL 288 5 Figure 142 110mm Lens Reading 2D Barcodes...
Page 301: ...IMAGING FEATURES 289 5 Figure 143 90mm Lens Reading 2D Barcodes...
Page 337: ......