IMAGING FEATURES
277
5
Client Devices Tab
ID:
For a single unit in a scan point there will be only one device added. An entry will need
to be made for each unit in a tunnel
Name:
Enter the name of the mounting location. Ex- Left_Front
Type:
Select the type of scanner from the drop-down list. In this example the
AV7000Client
is used.
Alarm:
Enter the Alarm level
Warning:
Enter the Warning level
Image Server Configuration Tab
URL:
IP address of WebSentinel PLUS (in most cases this will be 10.0.40.50)
Image Path:
Location in WebSentinel PLUS where the images are saved (
For Linux
Version:
/raid/images;
For Windows Version:
/images)
Once connected the scan point will be identified under Site View in the menu tree.The active
tunnel is identified by the green dot located to the right of the tunnel scan point name.
Summary of Contents for AV7000
Page 1: ...REFERENCE MANUAL AV7000 Linear Camera...
Page 11: ...xi GENERAL VIEW Figure 2 AV7000 Camera Front View Figure 3 AV7000 Camera Back View...
Page 97: ...ELECTRICAL INSTALLATION 85 3 3 11 7 Powered Outputs Figure 86 Powered Outputs NPN PNP...
Page 107: ...E GENIUS 95 4 Click Show to access Contents Index and Search options...
Page 243: ...IMAGING FEATURES 231 5 Ambient Light Ambient light can influence the signal DC level Good Read...
Page 295: ...IMAGING FEATURES 283 5 Figure 137 140mm Short Lens Reading Linear Barcodes...
Page 296: ...AV7000 LINEAR CAMERA REFERENCE MANUAL 284 5 Figure 138 110mm Lens Reading Linear Barcodes...
Page 297: ...IMAGING FEATURES 285 5 Figure 139 90mm Lens Reading Linear Barcodes...
Page 299: ...IMAGING FEATURES 287 5 Figure 141 140mm Short Lens Reading 2D Barcodes...
Page 300: ...AV7000 LINEAR CAMERA REFERENCE MANUAL 288 5 Figure 142 110mm Lens Reading 2D Barcodes...
Page 301: ...IMAGING FEATURES 289 5 Figure 143 90mm Lens Reading 2D Barcodes...
Page 337: ......