E-GENIUS
131
4
Field Name
Action/Definition
Index communication channel.
See section 4.5.5 for
Example Protocol Index configuration.
Max
Transmit
Distance
from System
Ref Point
(mm [in])
Enter the maximum distance in the field provided.
The AV7000 System sends information regarding a
parcel to the Video Coding System as soon as it is
available. This information for each image includes the
address where it has been saved, and the value and
position of each decoded label found on that image. If
images become available at different times (typically on
multisided AV7000 Systems) more than one message is
sent to the Video Coding System. The last one is
explicitly flagged. If this Max Distance from the Trigger is
reached for a parcel before all the expected images are
saved, the last message is sent to force the closure of
the parcel transaction.
Image
Saving
Index
Number
Select a number from the drop-down list. These
numbered selections are defined in
Image Savings |
Images Settings.
Include
Dimension
Data
Select this check box to include packages dimension
data with your image.
Include
Parcel
Surface
Coordinates
Select this check box to include package surface
coordinates with your image.
SC5000
Heartbeat
Timeout
Enter a time value in seconds to define the amount of
time between two message transmissions. If the input
timeout expires and no transmission has occurred, the
Heartbeat message will be transmitted.
SM Start
Position
When the SC5000 is used as a multiplexor, this identifies
which camera the barcode data is being received from.
Image
Saving
Index
Number
Select a number from the drop-down list. These
numbered selections are defined in
Image Savings |
Images Settings.
Heartbeat
Enable
Select
Disable, Unconditioned,
or
Conditioned
from the drop-down list. This
parameter is available when
Disable, Standard, Advanced,
or
Custom
is selected
from the
Data Output Protocol
drop-down list. It enables/disables the transmission of
the Heartbeat message signaling that the device is still active.
Disable:
The Heartbeat message is not transmitted
Unconditioned:
The Heartbeat message is always transmitted, even if
communication is still active
Conditioned:
The Heartbeat message is transmitted only when there is no
communication
Heartbeat Settings
Summary of Contents for AV7000
Page 1: ...REFERENCE MANUAL AV7000 Linear Camera...
Page 11: ...xi GENERAL VIEW Figure 2 AV7000 Camera Front View Figure 3 AV7000 Camera Back View...
Page 97: ...ELECTRICAL INSTALLATION 85 3 3 11 7 Powered Outputs Figure 86 Powered Outputs NPN PNP...
Page 107: ...E GENIUS 95 4 Click Show to access Contents Index and Search options...
Page 243: ...IMAGING FEATURES 231 5 Ambient Light Ambient light can influence the signal DC level Good Read...
Page 295: ...IMAGING FEATURES 283 5 Figure 137 140mm Short Lens Reading Linear Barcodes...
Page 296: ...AV7000 LINEAR CAMERA REFERENCE MANUAL 284 5 Figure 138 110mm Lens Reading Linear Barcodes...
Page 297: ...IMAGING FEATURES 285 5 Figure 139 90mm Lens Reading Linear Barcodes...
Page 299: ...IMAGING FEATURES 287 5 Figure 141 140mm Short Lens Reading 2D Barcodes...
Page 300: ...AV7000 LINEAR CAMERA REFERENCE MANUAL 288 5 Figure 142 110mm Lens Reading 2D Barcodes...
Page 301: ...IMAGING FEATURES 289 5 Figure 143 90mm Lens Reading 2D Barcodes...
Page 337: ......