![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-c-series/super-multi-nx-c-series_service-manual_3794977074.webp)
SiE12-411
Printed Circuit Board Connector Wiring Diagram
Printed Circuit Board Connector Wiring Diagram
63
1.3
Duct Connected Type
Connectors
Note:
Other designations
Control PCB Detail (PCB 1)
"
Refer to PCB (1) Control on P60.
Display PCB Detail (PCB 2)
1) S1 (on PCB 1) Connector for fan motor
2) S1 (on PCB 2) Connector for control PCB
3) S7
Connector for fan motor
4) S21
Connector for centralized control to 5 rooms
5) S26
Connector for display PCB
6) S32
Connector for room temp / Heat exchanger thermistor
1) V1
Varistor
2) JA
Address setting jumper
JB
Fan speed setting when compressor is OFF on thermostat
JC
Power failure recovery function
∗
Refer to page 257 for more detail.
3) SW1
Forced operation ON/OFF switch
4) LED1 (GRN) LED for operation
5) LED2 (YLW) LED for timer
6) LED3 (RED)
LED for HOME LEAVE operation