![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-c-series/super-multi-nx-c-series_service-manual_3794977034.webp)
SiE12-411
Specifications
Specifications
23
50Hz, 230V
Model
FTKS60BVMB
FTKS71BVMB
Rated Capacity
6.0kW Class
7.1kW Class
Front Panel Color
White
White
Air Flow Rates
m³/min
(cfm)
H
16.2 (572)
16.7 (590)
M
13.6 (480)
14.2 (501)
L
11.4 (402)
11.6 (409)
SL
10.2 (360)
10.6 (374)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
43
43
Speed
Steps
5 Steps, Silent and Auto
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.18
0.20
Power Consumption (Rated)
W
40
45
Power Factor
%
96.6
96.4
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×1,050×238
290×1,050×238
Packaged Dimensions (W×D×H)
mm
1,147×366×337
1,147×366×337
Weight
kg
12
12
Gross Weight
kg
17
17
Operation
Sound
H/M/L/SL
dBA
45/41/36/33
46/42/37/34
Sound Power
H
dBA
63
63
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
15.9
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D040782A
3D040783A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for Super Multi NX C-Series
Page 6: ...SiE12 411 Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...SiE12 411 vi Table of Contents...
Page 67: ...Specifications SiE12 411 56 Specifications...
Page 171: ...Instruction SiE12 411 160 System Configuration...
Page 225: ...Check SiE12 411 214 Service Diagnosis...
Page 295: ...SiE12 411 iv Index...